200 and 300 Series Service and Installation Manual
3
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
Installation - Models N225, N225L, N227 And N227L
Location
Units in this manual are intended for indoor use only. The
refrigeration system has been factory tested and should
require no further adjustment during installation.
For the most efficient refrigeration, be sure to provide
good air circulation inside and outside the unit.
Outside Cabinet: Be sure that the unit has access to
ample air. Avoid hot corners and locations near stoves
and ovens.
Counter Cutouts
For installation provide a cutout in the counter as
shown (see illustration 1 or 2). The counter must be
sturdy enough to hold the combined weight up to 300
pounds of the drop-in and the product stored inside.
The louver provided must be installed
in front of the condensing unit’s finned
coil (see illustration 3). A second cutout
must be made at the rear or end of
the equipment to allow air flow through
the unit. No louver is provided for the
second cutout. Any restriction to the
proper air flow, total or partial, will void
the compressor warranty.
TYPICAL
COUNTER
CABINET
LOUVER
13.00" x 25.00"
33.0cm x 63.5cm
LOUVER CUTOUT SIZE
12.00" x 23.50"
30.5cm x 59.7cm
(typical installation)
NOTE: A second cutout
(without louver) must
also be made to allow
proper air flow.
N225 N225L N227
or N227L DROP-IN
25.75"
65.4cm
28.0"
71.1cm
CUTOUT
.75"/1.9cm radius
1.00"/2.5cm (min.)
1.00"/2.5cm (min.)
COUNTERTOP
25.75"
65.4cm
14.62"
37.1cm
CUTOUT
.75"/1.9cm
radius
1.00"/2.5cm (min.)
1.00"/2.5cm (min.)
COUNTERTOP
Illustration 1. Model N225 & N225L cutout dimensions
Illustration 2. Model N227 & N227L cutout dimensions
Illustration 3. N225 N225L N227 & N227L louver installation
Electrical Connection
Refer to the amperage data on page 2, the serial tag,
your local code or the National Electrical Code to be
sure the unit is connected to the proper power source.
A protected circuit of the correct voltage and amperage
must be run for connection of the line cord.
If the unit does not operate after it is plugged in, check
the thermostat to see if it was inadvertently turned OFF
during installation.
The unit must be disconnected from
the power source whenever performing
service or maintenance functions.