Delfield SAHRL2-S Especificaciones

Busca en linea o descarga Especificaciones para No Delfield SAHRL2-S. Delfield SAHRL2-S Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
October 2005
Delfield 980 S. Isabella Rd., Mt. Pleasant, MI 48858
(989) 773-7891 or (800) 733-8829 • Fax (989) 773-3210
www.delfield.com
Please read this
manual completely
before attempting to
install or operate
this equipment!
Notify carrier of
damage. Inspect all
components imme-
diately. See page 6.
INSTALLATION &
OPERATION
MANUAL
Specification Line
®
Vista de pagina 0
1 2 3 4 5 6 ... 31 32

Indice de contenidos

Pagina 1 - OPERATION

October 2005Delfield 980 S. Isabella Rd., Mt. Pleasant, MI 48858(989) 773-7891 or (800) 733-8829 • Fax (989) 773-3210www.delfield.comPlease read this

Pagina 2

10DelfieldSELF CONTAINED HINGED GLASS DOOR PASS-THRU REFRIGERATORMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER CU. FT.

Pagina 3 - Table of Contents

11Specification LineSELF CONTAINED NARROW HINGED GLASS DOOR REACH-IN REFRIGERATORMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEM

Pagina 4 - Table of Contents – Continued

12DelfieldSELF CONTAINED SOLID DOOR ROLL-IN REFRIGERATORMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER CU. FT. SQ. FT. S

Pagina 5 - INTRODUCTION

13Specification LineSELF CONTAINED SOLID DOOR ROLL-IN FREEZERMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER CU. FT. SQ.

Pagina 6 - SERIAL NUMBER

14DelfieldSOLID DOOR SINGLE SECTION DUAL TEMP REFRIGERATOR/FREEZERPASS-THRU UNITSMODEL VOLTAGE AMPS STORAGE NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER

Pagina 7 - SPECIFICATIONS

15Specification LineSOLID DOOR SINGLE SECTION DUAL TEMP REFRIGERATOR/FREEZER REACH-INSMODEL VOLTAGE AMPS STORAGE NO. OF UNIT BTU/HR BTU/HR SHIP NEMANU

Pagina 8

16DelfieldSELF CONTAINED SOLID DOOR CONVERT-A-TEMP REACH-INMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER CU. FT. SQ. FT

Pagina 9

17Specification LineINSTALLATIONREACH-INS AND PASS-THRUSLocationCabinets represented in this manual are intended for indooruse only. Be sure the locat

Pagina 10 - Delfield

18DelfieldStabilizingIt is very important that all legs are properly adjusted tokeep the cabinet level, evenly distribute the weight and tomake sure t

Pagina 11 - Specification Line

19Specification LineLevelingAfter the cabinet has been placed in the desired location,cabinets with legs must be leveled. Level units from frontto bac

Pagina 12

2DelfieldIMPORTANT WARNING AND SAFETY INFORMATIONWARNINGRead this manual thoroughly before operating, installing, or performing maintenanceon the equi

Pagina 13

20DelfieldOperating ControlsREFRIGERATED WINE CABINETSRefrigerated wine cabinet units have a POWER ON/OFFswitch located on the front of the unit for c

Pagina 14

21Specification LineREFRIGERATED CABINETSRefrigerated cabinet units have a POWER ON/OFFswitch located on the front of the unit for controlling powerto

Pagina 15

22Delfield3. Adjust the time/temperature control for thefreezer to the desired temperature and timesettings.4. Set the temperature control for the des

Pagina 16

23Specification LineFailure to maintain a clean condenser coil can initially causehigh temperatures and excessive run times. Continuousoperation with

Pagina 17 - REACH-INS AND PASS-THRUS

24DelfieldProgrammingThree buttons are used for the programming: SET, UPand DOWN buttons. See Figure 7.NOTE: By lifting the gray plastic cover, but-to

Pagina 18 - ROLL-INS AND ROLL-THRU MODELS

25Specification LineTIMER CONTROLTwo and three sectionFreezer Defrost ControlAll two and three door freezers are equipped with aParagon Timer defrost

Pagina 19

26DelfieldOperationThe electric defrost controller is preset at the factory toprovide a defrost cycle every 6 hours (4 defrost per day).If it is neces

Pagina 20 - REFRIGERATED WINE CABINETS

27Specification LineLABOR OF 1-HOUR IS ALLOWED TO REPLACE:• Thermostat • Contactor/Relay• Door Jamb Switch • Transformer• Solenoid Coil • Evaporator/C

Pagina 21 - Freezer Compartment

28DelfieldSTANDARD TWO YEAR WARRANTY (Two year parts and labor, five year compressor)The Delfield Company (“Delfield”) warrants to the Original Purcha

Pagina 22 - Cleaning the Condenser Coil

29Specification LineADDITIONAL THREE YEAR PROTECTION PLAN (for motor-compressor only)In addition to the Standard One Year Warranty on theMotorCompress

Pagina 23 - Programming

3Specification LineSAFETY PRECAUTIONS... 2INTRODUCTION ...

Pagina 25 - Cycle Time

31Specification Line

Pagina 27

4DelfieldTable of Contents – Continued ROLL-INS AND ROLL-THRUS ... 18Location ...

Pagina 28

5Specification LineINTRODUCTIONGeneralModel numbers starting with the letters “SS” have astainless steel exterior and interior. Model numbersstarting

Pagina 29

6DelfieldRECEIVING AND INSPECTINGTHE EQUIPMENTCare should be taken during unloading so the equipmentis not damaged while being moved into the building

Pagina 30

7Specification LineSPECIFICATIONSHEATED ROLL-THRUMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER CU. FT. SQ. FT. SHELVES

Pagina 31

8DelfieldSOLID DOOR NARROW HOT FOOD CABINET REACH-INMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER CU. FT. SQ. FT. SHELV

Pagina 32 - DMSPECLINE 10/05

9Specification LineSELF CONTAINED SHALLOW SOLID DOOR REACH-IN REFRIGERATORMODEL VOLTAGE AMPS STORAGE SHELVES NO. OF UNIT BTU/HR BTU/HR SHIP NEMANUMBER

Comentarios a estos manuales

Sin comentarios